电信科学 ›› 2019, Vol. 35 ›› Issue (6): 25-32.doi: 10.11959/j.issn.1000-0801.2019162

• 专题:能源互联网技术与应用 • 上一篇    下一篇

综合能源系统故障态经济性最优运行策略

刘育权1,陈旭东2,熊文1,王莉1,陈东文2,李勇2()   

  1. 1 广州供电局有限公司,广东 广州510620
    2 上海交通大学机械与动力工程学院,上海 200240
  • 修回日期:2019-05-29 出版日期:2019-06-20 发布日期:2019-06-20
  • 作者简介:刘育权(1971- ),男,博士,广州供电局有限公司教授级高级工程师,主要研究方向为电力系统分析、智能电网、综合能源系统优化调度。|陈旭东(1993- ),男,上海交通大学机械与动力工程学院硕士生,主要研究方向为综合能源系统故障态运行方案。|熊文(1973- ),男,博士,广州供电局有限公司教授级高级工程师,主要研究方向为电力系统分析、智能电网、综合能源系统优化调度。|王莉(1969- ),女,广州供电局有限公司高级工程师,主要研究方向为电力系统继电保护、智能电网、综合能源系统优化调度。|陈东文(1993- ),男,上海交通大学机械与动力工程学院博士生,主要研究方向为综合能源系统规划、综合能源系统故障处理。|李勇(1969- ),男,博士,上海交通大学机械与动力工程学院副教授,主要研究方向为综合能源系统规划、综合能源系统优化控制。
  • 基金资助:
    国家重点研发计划项目(2016YFB0901300)

Economical operation strategy of integrated energy system under fault state

LIU Yuquan1,CHEN Xudong2,XIONG Wen1,WANG Li1,CHEN Dongwen2,LI Yong2()   

  1. 1 Guangzhou Power Supply Bureau Co.,Ltd.,Guangzhou 510620,China
    2 School of Mechanical Engineering,Shanghai Jiao Tong University,Shanghai 200240,China
  • Revised:2019-05-29 Online:2019-06-20 Published:2019-06-20
  • Supported by:
    The National Key Research and Development Program of China(2016YFB0901300)

摘要:

针对工厂提出了一种以多能转供为核心的综合能源系统故障态运行策略。首先,基于可测参数对各供能设备进行建模,建立了综合能源系统模型。而后提出了各类供能设备出现故障时最大供能能力计算方法,得到各设备出力约束条件,并建立冷热电多种能源的功率及能量平衡方程。进而以运行费用最低为优化目标,采用线性规划法对目标函数进行求解。最后以某工厂综合能源系统为算例,分析了不同故障条件下采用该策略后各设备出力变化的合理性,结果发现该策略具有 3 个特点:低负荷时运行成本控制效果显著;本策略调控效果主要受分时能源价格影响;最大外购资源曲线具有预测故障后成本变化趋势的作用。

关键词: 综合能源系统, 故障态, 多能转供, 运行策略优化

Abstract:

A fault-state operation strategy for integrated energy systems based on multi-energy transfer was proposed.Firstly,an integrated energy system model was built to model each energy-supply device in the system using actual measurable parameters.Then,the calculation method of maximum energy supply capacity when energy-supply device fails was introduced,and the power constraint conditions of each equipment were obtained,and the power balance equations of cold/heat/electricity power were established.Then,set the lowest operating cost as the optimization goal,the objective function was solved by the linear programming method.Finally,taking a factory-level integrated energy system as an example,the rationality of the output changes of each equipment after using this strategy under several fault conditions was analyzed.It is pointed out that the strategy has three characteristics:the cost control effect is significant at low load situation,remarkably impacted by time-sharing energy prices,the outsourcing resource curve can predict the change of operating costs when fault occurs.

Key words: integrated energy system, fault-state, multi-energy transfer, optimality of operation strategy

中图分类号: 